OSKSince 1986Special cables · Temperature sensing中文
← Technical resources

How to Choose an MI Thermocouple Cable Sheath

Start with the atmosphere or process medium, the normal and peak temperatures, and the available installation space. Then check whether the sheath alloy and the mineral-insulated cable construction can be supplied at the required outside diameter.

Compare the sheath materials against the actual atmosphere

  • Stainless steel 304 or 316 family. Start with the grade specified by the equipment drawing or process compatibility review. If an existing installation calls for 316L, state the exact grade and any required material certificate. Also tell us about immersion, cleaning agents or condensation.
  • 310S stainless steel. Consider it when a drawing or materials review calls for a high-temperature stainless grade. Provide the operating atmosphere, maximum exposure time and thermal cycling so the construction can be reviewed.
  • Alloy 600. A nickel-alloy option to discuss for high-temperature service. State the atmosphere explicitly, including vacuum, inert gas or combustion gas as applicable. Substitutions need the same process and fabrication checks as the original alloy.

These are selection references. The usable limit depends on conductor type, cable size, the process atmosphere and the finished assembly. Confirm the exact grade and available construction with OSK. For material and temperature context, see the Omega thermocouple reference guide.

Check diameter, tolerances and the intended bend

Give the nominal sheath outside diameter in millimetres and its tolerance. If the cable passes through a sleeve or fitting, provide the minimum bore, its tolerance and the smallest bend radius. At the same outside diameter, changing wall thickness or adding a second conductor pair changes the internal space available for conductors and insulation. Have the combination reviewed together.

For a finished probe rather than cable stock, also define the junction position, insertion length and termination. See how to specify MI cable versus a finished probe.

Send the inspection conditions with the coil specification

For a quote, include the thermocouple type, number of conductor pairs, sheath grade and outside diameter, continuous length per coil and total metres. List the end sealing and packaging you need. If insulation resistance is an acceptance requirement, provide the test voltage, temperature, measured length and acceptance limit so the test can be agreed before production.

See OSK 013 MI thermocouple cable · Request a cable quote