MI Thermocouple Cable or a Finished Probe?
Choose MI thermocouple cable if you plan to build the measuring junction, termination and mounting assembly yourself. If the sensor must install directly into equipment, request a finished probe based on the assembly dimensions and operating conditions.
When ordering MI thermocouple cable
Mineral-insulated thermocouple cable contains thermoelectric conductors, mineral insulation and a metal sheath. Send the thermocouple type, conductor pair count, sheath diameter and alloy, continuous length per coil and total quantity. Include test conditions with any insulation resistance requirement.
When ordering a finished probe
Along with type, diameter and sheath, specify the measuring junction, insertion length, fitting, lead and connector. Include the mating sleeve drawing for a slender probe or the measuring positions for a multipoint assembly.
What to include with either enquiry
State the operating temperature, medium, atmosphere and installation conditions. Include any drawings or sample details, then list required tolerances, inspection checks and documentation.
View MI thermocouple cable · Compare finished MI thermocouple families · Request a quote