How to Dimension a Slender MI Thermocouple for a Sleeve

A slender mineral-insulated thermocouple may meet its diameter and overall length requirements and still catch on a step in the sleeve or stop short of the intended sensing position. Mark the full insertion path and the mounting datum on the drawing.

Slender probe and sleeve schematic. A sheath diameter, B minimum bore, C insertion length, D step location.

Check the smallest bore along the insertion path

A marks the probe sheath diameter and B marks the narrowest sleeve bore. Include their tolerances. If the path has a step, constriction or entry chamfer, locate it as shown by D and give the dimensions of each section.

Measure insertion length from the mounting datum

C runs from the mounting datum to the probe tip. Use a defined face, such as the end face of a threaded fitting or the sealing face of a flange. Locate the measuring junction separately if it must sit at a specified offset from the tip.

Agree on straightness and inspection

Identify the probe section that requires straightness control. State the allowable deviation and the inspection method. A drawing or sample of the mating sleeve can help both teams check the fit before prototyping.

Include the assembly drawing, thermocouple type, operating temperature and termination requirements when requesting a quote.

View miniature MI thermocouples · Read about OSK’s straightening fixture · Request a drawing review